Stres psikologis memicu respons fisiologis berupa fluktuasi detak jantung, penurunan suhu perifer, dan perubahan konduktivitas kulit. Instrumen klinis konvensional saat ini mahal dan tidak portabel, sedangkan perangkat IoT terdahulu rentan bias akibat sensor tunggal, logika tegas (crisp logic) yang kaku, serta minimnya pra-pemrosesan data. Penelitian ini merancang sistem cerdas pendeteksi stres terintegrasi IoT menggunakan fusi multisensor (MAX30102, DS18B20, GSR) pada lapisan edge. Aliran data ditransmisikan secara real-time via Firebase ke aplikasi Android sebagai pusat komputasi utama. Aplikasi mengeksekusi Median Filter secara asinkron untuk meredam derau (noise), lalu mengumpankan data ke mesin inferensi Fuzzy Logic Mamdani dengan 27 basis aturan. Hasil pengujian terhadap 6 responden menunjukkan rata-rata kesalahan ukur instrumen sebesar 1,6% pada detak jantung dan 3% pada suhu tubuh. Median Filter terbukti efektif membuang lonjakan ekstrem sensor. Melalui defuzzifikasi Center of Gravity, aplikasi berhasil mengklasifikasikan status "TENANG / RILEKS", "KONDISI CEMAS", dan “STRES / TEGANG”secara presisi. Sistem ini membuktikan keandalan komputasi bergerak dalam mengelola ketidakpastian data biometrik layaknya diagnosis pakar.

Keywords:

Deteksi Stres, Fuzzy Logic, Internet of Things, Median Filter, Aplikasi Android.

##plugins.themes.default.displayStats.downloads##

##plugins.themes.default.displayStats.noStats##

References

[1] P. Cuijpers, A. Javed, and K. Bhui, "The WHO World Mental Health Report: A call for action," Br. J. Psychiatry, vol. 222, no. 6, pp. 227-229, 2023, doi: 10.1192/bjp.2023.9.

[2] WHO, World Mental Health Today. 2025. [Online]. Available: https://iris.who.int/

[3] T. L. Osborn, C. M. Wasanga, and D. M. Ndetei, Transforming mental health for all. 2022. doi: 10.1136/bmj.01593.

[4] R. Wang, O. Rezaeian, O. Asan, L. Zhang, and T. Liao, "Relationship Between Heart Rate and Perceived Stress in Intensive Care Unit Residents: Exploratory Analysis Using Fitbit Data," JMIR Form. Res., vol. 8, 2024, doi: 10.2196/60759.

[5] G. Birdee, R. Abraham, A. Diedrich, K. Kinney, and A. Gamboa, "Correlation of physiological stress as measured by heart rate and blood pressure variability and self-reported anxiety," pp. 1-12, 2025.

[6] J. A. Bigalke, A. M. Murvich, R. M. Brothers, and J. R. Carter, "Distal skin temperature is reduced in individuals with trait vulnerability to stress-related sleep disturbance," Am. J. Physiol. Regul. Integr. Comp. Physiol., vol. 329, no. 1, pp. R1-R12, 2025, doi: 10.1152/ajpregu.00053.2025.

[7] A. N. Phadke, K. Harasheh, and S. Gill, "Wearable IoT-Enabled Galvanic Skin Response Device for Objective Pain and Stress Monitoring: Hardware Design and Prototype Development," Sensors, vol. 26, no. 1, pp. 1-15, 2026, doi: 10.3390/s26010116.

[8] D. Dhake and Y. Angal, "A Comparative Analysis of EEG-based Stress Detection Utilizing Machine Learning and Deep Learning Classifiers with a Critical Literature Review," Int. J. Recent Innov. Trends Comput. Commun., vol. 11, no. 8s, pp. 61-73, 2023, doi: 10.17762/ijritcc.v11i8s.7175.

[9] J. W. Ahn, Y. Ku, and H. C. Kim, "A novel wearable EEG and ECG recording system for stress assessment," Sensors (Switzerland), vol. 19, no. 9, 2022, doi: 10.3390/s19091991.

[10] S. M. Gondowijoyo, R. Setiawan, and N. F. Hikmah, "Applying artificial neural network on heart rate variability and electroencephalogram signals to determine stress," Telkomnika (Telecommunication Comput. Electron. Control., vol. 22, no. 4, pp. 910-920, 2024, doi: 10.12928/TELKOMNIKA.v22i4.25832.

[11] M. M. Rahman, S. Toraskar, M. Hasan, and Z. Hao, "An Analytical Model of Motion Artifacts in a Measured Arterial Pulse Signal-Part I: Accelerometers and PPG Sensors," Sensors, vol. 25, no. 18, pp. 1-22, 2025, doi: 10.3390/s25185710.

[12] R. Nurhakim, S. A. T. Al Azhima, N. F. A. Hakim, M. Al Qibtiya, L. Maulana, and S. Rohman, "Medication box management system with automatic dosing integrated with IoT-based Android app and Firebase," Bull. Electr. Eng. Informatics, vol. 14, no. 2, pp. 966-977, 2025, doi: 10.11591/eei.v14i2.8470.

[13] R. Uddin and I. Koo, "Real-Time Remote Patient Monitoring: A Review of Biosensors Integrated with Multi-Hop IoT Systems via Cloud Connectivity," Appl. Sci., vol. 14, no. 5, 2024, doi: 10.3390/app14051876.

[14] A. Z. Saputra, M. T. Habibie, and M. C. Irawan, "Rancang Bangun Alat Monitoring Detak Jantung dan Suhu Tubuh Berbasis Internet Of Things (Iot)," J. Ris. dan Apl. Mhs. Inform., vol. 6, no. 01, pp. 86-92, 2025, doi: 10.30998/jrami.v6i01.10459.

[15] Irmayanti, H. Tari Mokui, dan Wa Ode Siti Nur Alam, and C. Author, "Sistem Pendeteksi Stres pada Manusia Menggunakan Metode Fuzzy Logic Berbasis Internet of Things," J. Fokus Elektroda, vol. 7, no. 3, pp. 185-192, 2022, [Online]. Available: https://elektroda.uho.ac.id/

[16] I. Program, P. E. Program, E. E. Program, M. Processing, and T. Srivijaya, "DESIGN AND IMPLEMENTATION OF A SMARTPHONE- BASED IOT CONTROL SYSTEM FOR ELECTRIC HOSPITAL BEDS IN HOME HEALTHCARE APPLICATIONS," vol. 103, no. 20, pp. 8292-8306, 2025.

[17] C. Suman Mogadati and C. Nayak, "Enhancing PPG Signal Integrity Using Manta Ray Foraging Optimization-Based Adaptive Filtering," IEEE Access, vol. 13, pp. 192210-192227, 2025, doi: 10.1109/ACCESS.2025.3630684.

[18] A. Adeli and M. Neshat, "A Fuzzy Expert System for heart disease diagnosis," Proc. Int. MultiConference Eng. Comput. Sci. 2022 IMECS 2022, vol. I, pp. 134-139, 2022.